BR250 – Type BR BRKR 50A/2 Pole 120/240V 10K

$
(per )

(Each)

$27.26

(Each)

$

(per 5)

$

(per 25)

Availability:

In Stock Locally

Description

$27.26

Category: Brand:

Description

Quick Specs
Catalog Number BR250
Vendor Code ETN
Manufacturer Eaton
Manufacturer’s Part Number BR250
Description Type BR BRKR 50A/2 Pole 120/240V 10K
Standard Trip Circuit Breaker, 50 A, Common Tripping Mechanism, Line and Load Lug Terminal, Plug-On, 120/240 V Ac, 3 In Overall Height, 3 In Overall Length, 2 In Overall Width
Slang Terms
Categories Standard Trip Plug – 2 Pole Standard Trip Plug-In
Classification Loadcenter Plug In Breakers and Accessories
UNSPSC 39121601 – Circuit breakers
UPC/GTIN 786676363051 / 00786676363051
Weight per unit 0.5 (lbs/each)
Price & Packaging
Minimum Order Quantity 1
Unit $27.26 (Each)
Carton $136.30 (Per 5)
Standard Packaging $681.50 (Per 25)
Resources
Images BR250 – Small Image
BR250 – Large Image (multiple)
Attachments BR250 – Specification Sheet
Brochures BR250 – Brochure
Other Links BR250 – Other (multiple)
Features
Current Rating 50 A
Voltage Rating 120/240 V ac
interrupt rating 10 kAIC
Poles 2
Dimensions and Weight
Overall Length 3 in
Descriptions
Product Type Standard Trip Circuit Breaker
Short Description 2P Standard Trip Circuit Breaker, 50 A, 120/240 VAC w/Trip Flag
Long Description Standard Trip Circuit Breaker, 50 A, Common Tripping Mechanism, Line and Load Lug Terminal, Plug-On, 120/240 V ac, 3 in Overall Height, 3 in Overall Length, 2 in Overall Width
Features A branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code. The Combination Type AFCI is required in the 2005, 2008, and 2011 National Electrical
extra long description ETN BR250 Type BR Breaker 50A/2 Pol
Description TYPE BR BRKR 50A/2 POLE 120/240V 10K
Additional Information
Tripping Mechanism Common
Terminal Connection Type Line and Load Lug
Mounting Type Plug-On
circuit breaker type Standard Trip Circuit Breaker
Overall Width 2 in
for use with Type BR Loadcenters
Standards Met UL Listed 489; Federal Specifications Classification W-C375; IGCC 4813
Overall Height 3 in
dimensions 3.0000 IN X 2.0000 IN X 3.0000 IN
Trip Type Common breaker trip
Manufacturer Information
Brand Eaton Corp Viton(R)
Manufacturers Part Number BR250
GTIN 00786676363051
UPC 786676363051
Taxonomies, Classifications, and Categories
Category Description Loadcenter Plug In Breakers and Accessories
Type Thermal magnetic circuit breakers
Packaging
Weight per each 0.5
Carton 5
Package 25
Uses, Certifications, and Standards
Application Datacenters – IT Space: CI and Hyper ConvergedOtherGeneration – Renewable Energy – Alternative EnergyMarine Vessels and Equipment – Marine Vessels and Equipment – OtherGeneration – Conventional Energy – Conventional Energy
standard UL 489, Federal Specifications Classification W-C375